| 1 | Ceiling-Mounted 360° PIR Switch | Open-plan offices, corridors, classrooms, and retail areas | Flush or surface ceiling mount | 360°; commonly 6–8 m diameter at a 2.5–3 m mounting height | Up to approximately 8 m | Approx. 10 seconds–30 minutes | 100–240 V AC or low-voltage sensor with relay controller | Often 5–10 A resistive; LED load must be checked separately | Usually IP20 indoors | Broad coverage with minimal blind spots | Verify ceiling height, neutral-wire requirement, and LED inrush-current rating |
| 2 | Wall-Mounted 180° PIR Switch | Stairways, entrances, hallways, and small rooms | Wall or corner mount | 180°; commonly 8–12 m across the detection field | Typically 8–12 m | Approx. 5 seconds–20 minutes | 100–240 V AC | Commonly 5–10 A resistive; LED compatibility varies | Usually IP20; outdoor versions may be IP44 or higher | Easy retrofit for standard wall locations | Check mounting height, side-entry sensitivity, and minimum load |
| 3 | PIR Switch with Manual Override | Bedrooms, meeting rooms, utility spaces, and private offices | Wall-box or surface wall mount | Usually 120–180° | Approximately 6–10 m | Approx. 30 seconds–30 minutes, plus manual ON/OFF control | 100–240 V AC | Typically 5–10 A, subject to the lighting-load type | Usually IP20 indoors | Allows users to override automatic switching | Confirm whether override is latching, momentary, or timer-based |
| 4 | PIR Switch with Adjustable Lux Threshold | Daylight-dependent lighting in corridors, toilets, and offices | Ceiling or wall mount | Approximately 120–360°, depending on lens design | About 6–10 m | Approx. 10 seconds–30 minutes | 100–240 V AC | Often 5–10 A resistive; use a rated relay for larger LED banks | Usually IP20 indoors | Prevents unnecessary operation in bright conditions | Check lux adjustment range and whether the sensor can be exposed to the controlled light |
| 5 | Outdoor PIR Sensor Switch with Photocell | Driveways, entrances, pathways, loading areas, and security lights | Wall or surface mount | Typically 120–180° | Approximately 8–15 m | Approx. 5 seconds–15 minutes | 100–240 V AC | Commonly 5–10 A resistive; LED wattage requires derating checks | Prefer IP44–IP65 for exposed outdoor locations | Combines motion detection with dusk-to-dawn control | Verify UV-resistant housing, condensation protection, and local outdoor wiring rules |
| 6 | PIR Switch for LED Lighting Loads | LED downlights, panels, strip-light drivers, and compact luminaires | Ceiling, wall, or in-line installation | Approximately 120–360° | About 6–10 m | Approx. 10 seconds–30 minutes | 100–240 V AC, depending on wiring design | Must specify LED load and inrush-current capability; nominal ratings vary widely | Usually IP20 indoors | Designed around modern low-energy lighting | Confirm trailing-edge/leading-edge compatibility, minimum load, and driver inrush rating |
| 7 | Low-Voltage PIR Sensor with Relay Module | Building automation, HVAC control, and centralized lighting systems | Ceiling or wall sensor plus remote relay | Typically 90–360° | Approximately 6–12 m | Approx. 5 seconds–30 minutes | Commonly 12–24 V DC or AC | Sensor output is often low-current; relay rating depends on the separate module | Indoor versions commonly IP20 | Separates sensing from high-voltage switching | Check control protocol, cable length, polarity, relay contact form, and fail-safe behavior |
| 8 | PIR Switch with HVAC or Auxiliary Output | Energy-saving control of lights, fans, and ventilation equipment | Ceiling or wall mount | Usually 120–360° | Approximately 6–10 m | Approx. 30 seconds–30 minutes | 100–240 V AC or low-voltage control versions | Lighting output commonly 5–10 A; auxiliary output may be lower | Typically IP20 indoors | Can coordinate occupancy-based lighting and ventilation | Verify separate output ratings, contact isolation, and motor-load suitability |
| 9 | PIR Switch with Neutral-Free Wiring Option | Retrofit projects where a neutral conductor is unavailable | Wall-box installation, with selected ceiling variants | Commonly 120–180° | Approximately 6–9 m | Approx. 10 seconds–20 minutes | Usually 100–240 V AC | Often requires a minimum load; low-wattage LED lamps may need a bypass component | Usually IP20 indoors | Useful for upgrading existing switch points | Check minimum load, flicker risk, bypass requirements, and compatibility with two-way switching |
| 10 | Multi-Sensor PIR Switch with Remote Commissioning | Commercial buildings, warehouses, schools, and large retrofit programs | Ceiling mount with remote-control or commissioning interface | Typically 360°; coverage varies by lens and mounting height | Approximately 8–15 m | Approx. 10 seconds–60 minutes | 100–240 V AC or low-voltage system architecture | Relay, 0–10 V, DALI, or other control output; verify the specific interface | Commonly IP20 indoors; protected versions may be higher | Fast configuration and better control for large installations | Confirm commissioning method, control-system compatibility, cybersecurity requirements, and regional approvals |